The specific content of the daily maintenance of the axial piston pump
time:2016-02-23 17:11:21 views:16812
The measurement of axial piston pump (including motor insulation), should use 500V megohmmeter. If only the axial piston pump were detected to remove all terminals connected with the axial piston pump external wiring. Cleaning device, the main circuit terminals are shorted wire, with the use of megger test, if megohmmeters instructions above 5Mn, it is normal, the purpose is to reduce the number of shake measure.
The specific contents of daily maintenance can be divided into: the operation data recording, fault record. Every day to record the axial plunger pump and motor operation data, including axial piston pump output frequency, output current, output voltage, axial piston pump internal DC voltage, radiator temperature parameters, control and reasonable data compared to early detection of potential failures. Axial piston pump such as fault tripping, record fault code, and operating conditions of the axial piston pump trip, to specific analysis of the causes of failure.